GY5110 cable pairing device
GY341 Transmission Line Parameter Test System
GY663 cable fault tester
GY665 full intelligent multiple pulse cable fault t
GYSBY cable identification device (off line)
GY16C Transmission Line Fault Distance Tester
GYWXL wireless high and low voltage clamp ammeter (
GY803 capacitance and inductance tester
Technical Specfications:
Features |
High-voltage AC current measurement, low-voltage AC current, leakage current measurement, online AC current monitoring |
power supply |
DC6V alkaline dry battery (1.5V AAA × 4) |
test method |
Clamp CT, integration method |
transfer method |
Wireless transmission, the maximum distance of straight line transmission is about 30m |
Display mode |
4-digit LCD display, backlight function, suitable for dark places |
LCD size |
47mm × 28.5mm |
Meter size |
Width, height and thickness: 76 × 255 × 31mm3 |
Jaw size |
φ48mm |
Sampling rate |
About 2 times / second |
Measuring range |
0.1mA ~ 1000A (50 / 60Hz automatic) |
Resolution |
0.1mA |
Shift |
0.1mA ~ 1000A automatic switching shift |
Test accuracy (23 ℃ ± 5 ℃, below 80% RH) |
0.1mA~299mA:±1%±3dgt |
0.30A~9.99A:±1.5%±5dgt |
|
10.0A~199.9A:±2%±5dgt |
|
200A~399A:±2.5%±5dgt |
|
400A~600A:±3%±5dgt |
|
601A~1000A:±4%±5dgt |
|
Line voltage |
Line test below 60kV (operation with 5 insulation rods) |
data storage |
99 groups, "MEM" symbol indicates during storage, "FULL" symbol flashes to indicate that the storage is full |
PEAK hold |
Automatically maintain the test value at a high position, usually in the test mode, long press the HOLD key until the PEAK light is on, that is, the PEAK hold function is turned on |
Data retention |
In normal test mode, press the HOLD key to hold the data, the "HOLD" symbol is displayed |
Data review |
"MR" symbol indicates that the stored data can be read up and down |
Overflow display |
Overrange overflow function: "OL A" symbol display |
No signal indication |
When the receiver does not receive the transmission signal, it dynamically displays the "no--" symbol |
Automatic shut-down |
About 15 minutes after starting up, the meter will automatically shut down to reduce battery consumption |
battery voltage |
When the battery voltage is lower than 4.8V, the battery voltage low symbol is displayed, reminding to replace the battery |
Instrument quality |
Detector: about 335g (including battery), total mass of the instrument: about 2.5kg (including insulating rod and battery) |
Working temperature and humidity |
-25 ℃ ~ 40 ℃; below 80% Rh |
Storage temperature and humidity |
-10 ℃ ~ 60 ℃; below 70% Rh |
Insulation rod size |
φ32mm, 1m / section (5 sections) |
Dielectric strength |
AC 100kV / rms (between Section 5 insulation rod and high voltage current clamp core) |
structure |
Anti-drip type Ⅱ |
Product Features:
1.The innovative integrated design of the clamp head and the guide area ensures the high precision,
high reliability and high stability of the uninterrupted test all the year round
2. Peak hold, data hold, data storage, infrared transmission and other functions
3. The insulating rod is light and has the characteristics of moisture resistance, high temperature resistance,
impact resistance, bending resistance, high insulation, and scalability.
4. Adopt new CT technology and mask digital integration technology