DNC three-phase energy meter field calibrator
GY481 Three-phase precision programmable power supp
GY-HG Intelligent Transformer Calibrator
GY9201 AC and DC indicator verification device
GY4501 single-phase energy meter field calibrator
Transformer load box
GYCT standard current transformer
GY series current riser
GYPT standard voltage transformer
GY4500 Secondary Voltage Drop Tester
Technical Specifications: |
Ratio range |
Full range measurement (electromagnetic type) ± 0.2% |
||
Error measurement range |
Primary voltage: 3-110kV / √3 (non-standard primary voltage is also permitted) |
||
Secondary voltage |
100V,100V/√3 、6kV/100V 10kV/100v 、20kV/100V 35kV/100V、 6kV/√3/100V/√3、10kV/√3/100V/√3 、20kV/√3/100V/√3、 |
||
Power factor |
0.0-1.0 |
||
Limit error |
±0.05% |
||
DC Resistance |
0.0-0.1Ω |
±3% |
|
0.1-50Ω |
±1% |
||
PT secondary load |
1VA-500VA |
±2% |
|
Verification |
voltage range |
0-100V (meter error 0.5%) |
|
Ratio Difference |
0.001%-3% (100V) |
||
Angular difference |
0.00′-50′(100V) |
||
Tolerance |
△X=±(2%×X+2%×Y±2 digit) |
||
△Y=±(2%×X+2%×Y±2 digit) |
|||
Admittance |
0.1mS-99.9mS |
||
Tolerance |
△X=±(2%×X+2%×Y±2 digit) |
||
△Y=±(2%×X+2%×Y±2 digit) |
|||
Power Supply |
AC 220V ±10%/50Hz ±2% |
||
Ambient temperature |
0-40℃ |
||
Power consumption |
30W(static)150W(operating) |
||
Ambient temperature |
0-40℃ |
||
Environment humidity |
25℃时<85% |
||
Total Weight |
≤6kg |
||
Dimension |
37cm×28cm×16cm |
Product Features:
1. Meet the 20% -120% regulation point error (angle difference, ratio difference) detection of voltage transformers for
measurement in compliance with national regulations.
2. Complete the measurement at one time and display (measure according to the regulations) the error of the regulation
points (angle difference, ratio difference) between the upper limit load and the lower limit load of the voltage transformer.
3. Complete the measurement at one time and display the procedure point error (angle difference, ratio difference) of
the two sets of actual arbitrary load of the voltage transformer.
4. Detect the transformation ratio and polarity of the voltage transformer.
5. Measure the actual secondary load on site.
6. The instrument can display the test wiring diagram, which is convenient for the operator to check the wiring.
7. The instrument intelligently prompts the wiring error to ensure the safety of the instrument and the accuracy of detection.
8. Adopt the principle of small voltage test to actively protect the safety of the operators.
9. 320 * 240 large-screen LCD display, full Chinese interface. Wiring and operation are simple and easy to carry.
10. Various measurement data can be stored and printed to facilitate user query.
11. The instrument can be used with our company's on-site portable rechargeable test power supply, which is convenient
for taking power on site.