SGC-2 salt deposit density tester
GYFC-2G Lightning Protection Element Tester
GY-15 Insulator Distribution Voltage Measuring Inst
JSYF9 arrester discharge counter calibrator
GY-BLQ Zinc Oxide Arrester DC Parameter Tester
GY-BL zinc oxide lightning arrester tester
GY508 Insulator Grey Density Tester
SGC-6 Insulator Zero Tester
Technical specs |
Measuring range |
tolerance |
Test Conditions |
Initial action voltage (U1mA) |
0~1700V |
≤±2%±1d |
1mA±5μA |
Leakage current (I0.75U 1mA) |
0~199.9μA |
≤±2μA ±1d |
0.75 U1mA |
Discharge tube measurement |
|||
Technical specs |
Measuring range |
tolerance |
Test Conditions |
DC breakdown voltage (Vsdc) |
(20~1700)V |
≤±2%±1d |
Voltage rise rate: 100V / S ± 10% |
Other parameters |
|||
Insulation resistance |
6MΩ(500V) |
||
Withstand voltage |
AC1.5kV 50Hz 1min |
||
Operating temperature and humidity |
0~+40℃,≤85%RH |
||
Storage temperature and humidity |
-10℃~+50℃,≤90%RH |
||
power supply |
DC15V |
||
Power consumption |
8W |
||
Instrument size |
208×190×78mm3 |
||
weight |
≤1k |
Product Features:
1. Lightning protection component tester can measure the main parameters of voltage-limiting breakdown and overvoltag
ignition components.
2. The initial voltage can be set in advance, 20V ~ 1700VHJFC-2G type, 0 ~ 1999VHJFC-2GB type are continuously adjustable.
3. 1/2 LCD digital display, high accuracy, good reliability, intuitive and clear.
4. When testing the varistor, it can automatically give an accurate 1mA constant current and 0.75U1mA voltage.
5. During the gas discharge tube test, the test voltage rises linearly at a rate of 100V / S.
6. Choose continuous measurement, you can conduct uninterrupted testing of batches of samples.
7. With high-voltage short-circuit protection, over-current protection, self-test and other functions.